  page 1 specification for approval customer : description : thermoelectric cooler 200w customer part no : rev. : delta model no : HET200PC-B rev. : 03 sample issue no : sample issue date : apr.22 2014 modify history rev. description drawn approved issue date 00 issue spec . nick wang ken chou 2013/10/22 01 add the grounding feature on case nick wang ken chou 2013/11/20 02 update the grounding area nick wang ken chou 201 3/11/25 03 modify the airflow & certified safety nick wang ken chou 2014/04/22 delta electronics, inc. 252, shang ying road, kuei san tel : 8 86-(03)-3591968 taoyuan hsien 333, taiwan, r. o. c. fax : 886-(03)-3591991 please send one copy of this specification back aft er you signed approval for production pre-arrangement approved by : date :
me ee ce 00 issue spec t 10/25'13 t ?? 10/25'13 ? t 11/20'13 t ?? 11/20'13 ? t 11/25'13 t ?? 11/25'13 ? t t ?? ?

page 2 table of content 1.
page 3 specification for approval customer : description : thermoelectric cooler 200w customer p/n : rev . : delta model no. : HET200PC-B rev . : 03 sample revision : is sue no. : sample issue date : qu antity : sets
page 4 part no. : delta model no. : HET200PC-B 1. description 1-1. general description : the thermoelectric cooler (tec) is designed for dir ect air to air heat removal in the cabinet. it is easy to be installed in the cabinet (recommended on the door of the cabinet) with the n uts. the internal and external air circulation loops of the tec module are separated to prevent the entry of dust, humidity an d dirt. the unit conforms to ip55 protection rating on the external air circu it. 1-2. main feature (operating 48vdc at 25 ? ?? ? ? ?? ?
page 5 part no. : delta model no. : HET200PC-B 1-3. dimension 1-3-1 drawing (1) material : case aluminum sheet , t=1.5mm (2) finish : power paint 75~120um, (3) color : ral 7032 (4) dimension tolerance: x.x [x.xx] : 1.0mm [0.04?] x.xx [x.xxx] : 0.3mm [0.012?]
page 6 part no. : delta model no. : HET200PC-B 1-3-2 mounting panel cutout : :
page 7 part no. : delta model no. : HET200PC-B 1-4. maintenance 1-4-1. be sure to disconnect power supply before di sassembly tec module from customer cabinet. 1-4-2. please refer to delta authorized engineers f or tec module component replacement service, no allow unauthorize d personnel to repair the unit. 1-4-3. if the replacement by user himself is necessary, please refer to the exploded drawing shown as previous page and below d escription for disassembly. external fan: disassemble mounting screw of externa l fan via screw driver & pull out the connector. internal fan: disassemble mounting screw of internal fan via screw driver & pull out the connector . controller: need to disassemble internal f an first , then pull-out all cable connection on controller , take off mounting screw of controller finally . tec device: due to tec device have waterpro of sealant protection and thermal conductive compound with heat-sink, ple ase kindly ship back to delta for replacement.
page 8 part no. : delta model no. : HET200PC-B 1-5. thermal path and airflow baffle the thermal exchange path is shown in the figure be low.
page 9 part no. : delta model no. : HET200PC-B 2. electrical specification 2-1. indicator & connector connector " -48v vdc " mate with jwt c4201wr0-2*3pn l 2-2. cooling performance vs temperature difference 2-3. tec work temperature range HET200PC-B has two work status, cooling and heating , according to the cabinet internal temperature (detect by on-b oard ntc).
page 10 part no. : delta model no. : HET200PC-B 2-4. interface HET200PC-B control-board interface is as diagram. t he function will be described as following:  led "fan" (green) : fan normal (red) : fan failed (blink green) : fan normal in test process (blink red) : fan failed in test process  led "tec" (green) : tec normal (red) : tec failed  led "status" (green) : HET200PC-B work in cooling mode (red) : HET200PC-B work in heating mode (dark): HET200PC-B tec function off (blink red): temperature sensor fail  clean/test there is an auto test button on HET200PC-B, user ca n press this button to run het200pb-a heating and cooling process, the process is about 3~4 mints. user can turn off this function by pressing this button agai n.
page 11 part no. : delta model no. : HET200PC-B alarm contact: alarm dry contact: (max. 60vdc 400ma or 125vac, 400 ma)  pin1 to pin3 ?close?: normal  pin1 to pin3 ?open?: fan , tec or sensor failed  pin2 to pin3 ?open?: normal  pin2 to pin3 ?close?: fan , tec or sensor failed for engineer setup tec work temperature, HET200PC-B contain rs-485 function (non-isolated, half-duplex) to adjust heat ing or cooling on/off temperature. the process should be under electric p recautions. operation steps please consult the file ?hex200pc-b setting instruction?.
page 12 part no. : delta model no. : HET200PC-B 3. environmental conditions 3-1. operating temperature: -20c ~ +55c ( -4f ~ 131f) 3-2. storage temperature: -40c ~ +65c (-40f ~ 149f) 3-3. humidity external air circuit: 0 ~ 100% rh internal air circuit: 0 ~ 90% rh, non-condensing 3-4. protection rating ip55 (iec60529) on external side with mounting on d oor. 3-5. mtbf fan lifetime is expected to have a minimum l10 life of 80,000 hours continuous operation at 40c with 15 ~ 65%rh at 48 voltage 4. certified safety 4-1. ul , cul, ce , tuv 5. user cable each HET200PC-B will provide 1 cable with shipment. 5-1 power cable
doc. no: fmbg-es form 001 rev. 0001 date: june 24, 2009 application notice 1. delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the speci fication. 2. a written request should be submitted to delta p rior to approval if deviation from this specification is required. 3. please exercise caution when handling fans. dam age may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fan was hard-dropped to the production floor. 4. except as pertains to some special designs, ther e is no guarantee that the products will be free from any such safety problems or failures a s caused by the introduction of powder, droplets of water or encroachment of insect into the hub. 5. the above-mentioned conditions are representativ e of some unique examples and viewed as the first point of reference prior to all othe r information. 6. i t is very important to establish the correct polari ty before connecting the fan to the power source. positive (+) and negative (-). dama ge may be caused to the fans if connection is with reverse polarity, if there is no foolproof method to protect against such error specifically mentioned in this spec. 7. delta fans without special protection are not su itable where any corrosive fluids are introduced to their environment. 8. please ensure all fans are stored according to t he storage temperature limits specified. do not store fans in a high humidity environmen t. we highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months. 9. not all fans are provided with the lock rotor pr otection feature. if you impair the rotation of the impeller for the fans that do not h ave this function, the performance of those fans will lead to failure. 10. please be cautious when mounting the fan. inco rrect mounting of fans may cause excess resonance, vibration and subsequent noise . 11. it is important to consider safety when testing the fans. a suitable fan guard should be fitted to the fan to guard against any potential fo r personal injury. 12. except where specifically stated, all tests are carried out at room (ambient) temperature and relative humidity conditions of 25 o c, 65% rh. the test value is only for fan performance itself. 13. be certain to connect an ? 4.7f or greater? ca pacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power.


▲Up To Search▲   

 
Price & Availability of HET200PC-B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X